primitivus: use of new logging system:

- default output is \\memory
    - logs can be seen with :messages command
    - now useless writeLog method has been removed
This commit is contained in:
Goffi 2014-05-05 20:12:19 +02:00
commit 39989cc985
2 changed files with 80 additions and 43 deletions

View file

@ -79,6 +79,7 @@ class Const(object):
LOG_BACKEND_BASIC = 'basic'
LOG_BASE_LOGGER = 'root'
LOG_TWISTED_LOGGER = 'twisted'
LOG_OPT_SECTION = 'DEFAULT' # section of sat.conf where log options should be
LOG_OPT_PREFIX = 'log_'
# (option_name, default_value) tuples
LOG_OPT_COLORS = ('colors', 'true') # true for auto colors, force to have colors even if stdout is not a tty, false for no color
@ -91,7 +92,6 @@ class Const(object):
LOG_OPT_OUTPUT_MEMORY_LIMIT = 50
LOG_OPT_OUTPUT_FILE = 'file' # file is implicit if only output
LOG_OPT_OUTPUT = ('output', LOG_OPT_OUTPUT_SEP + LOG_OPT_OUTPUT_DEFAULT) # //default = normal output (stderr or a file with twistd), path/to/file for a file (must be the first if used), //memory for memory (options can be put in parenthesis, e.g.: //memory(500) for a 500 lines memory)
LOG_OPTIONS = (LOG_OPT_COLORS, LOG_OPT_LEVEL, LOG_OPT_FORMAT, LOG_OPT_LOGGER, LOG_OPT_OUTPUT)
LOG_LVL_DEBUG = 'DEBUG'
LOG_LVL_INFO = 'INFO'
LOG_LVL_WARNING = 'WARNING'
@ -115,3 +115,10 @@ class Const(object):
ANSI_BOLD = '\033[1m'
ANSI_BLINK = '\033[5m'
ANSI_BLINK_OFF = '\033[25m'
@classmethod
def LOG_OPTIONS(cls):
"""Return options checked for logs"""
# XXX: we use a classmethod so we can use Const inheritance to change default options
return(cls.LOG_OPT_COLORS, cls.LOG_OPT_LEVEL, cls.LOG_OPT_FORMAT, cls.LOG_OPT_LOGGER, cls.LOG_OPT_OUTPUT)

View file

@ -169,6 +169,18 @@ class FilterName(object):
log_record.name = dict_record['name']
return self.filter(log_record) == 1
def memoryGet(size=None):
"""Return buffered logs
@param size: number of logs to return
"""
if not C.LOG_OPT_OUTPUT_MEMORY in _handlers:
raise ValueError('memory output is not used')
if _backend == C.LOG_BACKEND_STANDARD:
mem_handler = _handlers[C.LOG_OPT_OUTPUT_MEMORY]
return (log_msg for log_msg in mem_handler.buffer[size if size is None else -size:])
else:
raise NotImplementedError
def _getProfile():
"""Try to find profile value using introspection"""
@ -509,7 +521,11 @@ class ConfigureTwisted(ConfigureBasic):
class ConfigureStandard(Configure):
def __init__(self, level=None, fmt=C.LOG_OPT_FORMAT[1], output=C.LOG_OPT_OUTPUT[1], logger=None, colors=False, force_colors=False):
def __init__(self, level=None, fmt=None, output=None, logger=None, colors=False, force_colors=False):
if fmt is None:
fmt = C.LOG_OPT_FORMAT[1]
if output is None:
output = C.LOG_OPT_OUTPUT[1]
super(ConfigureStandard, self).__init__(level, fmt, output, logger, colors, force_colors)
def preTreatment(self):
@ -559,7 +575,7 @@ class ConfigureStandard(Configure):
def configureColors(self, colors, force_colors):
import sys
self.with_color = colors & (sys.stdout.isatty() or force_colors)
self.formatter.with_color = colors & (sys.stdout.isatty() or force_colors)
if not colors and force_colors:
raise ValueError("force_colors can't be used if colors is False")
@ -579,8 +595,11 @@ class ConfigureStandard(Configure):
hdlr = logging.StreamHandler()
self._addHandler(root_logger, hdlr)
elif handler == C.LOG_OPT_OUTPUT_MEMORY:
import logging.handlers
hdlr = logging.handlers.BufferingHandler(options)
from logging.handlers import BufferingHandler
class SatMemoryHandler(BufferingHandler):
def emit(self, record):
super(SatMemoryHandler, self).emit(self.format(record))
hdlr = SatMemoryHandler(options)
_handlers[handler] = hdlr # we keep a reference to the handler to read the buffer later
self._addHandler(root_logger, hdlr)
elif handler == C.LOG_OPT_OUTPUT_FILE:
@ -640,23 +659,31 @@ def _parseOptions(options):
level = C.LOG_LVL_INFO
options[LEVEL] = level
def satConfigure(backend=C.LOG_BACKEND_TWISTED):
def satConfigure(backend=C.LOG_BACKEND_STANDARD, const=None):
"""Configure logging system for SàT, can be used by frontends
logs conf is read in SàT conf, then in environment variables. It must be done before Memory init
@param backend: backend to use, it can be:
- C.LOG_BACKEND_BASIC: print based backend
- C.LOG_BACKEND_TWISTED: Twisted logging backend
- C.LOG_BACKEND_STANDARD: standard logging backend
@param const: Const class to use instead of sat.core.constants.Const (mainly used to change default values)
"""
if const is not None:
global C
C = const
import ConfigParser
import os
log_conf = {}
config = ConfigParser.SafeConfigParser()
config.read(C.CONFIG_FILES)
for opt_name, opt_default in C.LOG_OPTIONS:
for opt_name, opt_default in C.LOG_OPTIONS():
try:
log_conf[opt_name] = os.environ[''.join((C.ENV_PREFIX, C.LOG_OPT_PREFIX.upper(), opt_name.upper()))]
except KeyError:
try:
log_conf[opt_name] = config.get('DEFAULT', C.LOG_OPT_PREFIX + opt_name)
except ConfigParser.NoOptionError:
log_conf[opt_name] = config.get(C.LOG_OPT_SECTION, C.LOG_OPT_PREFIX + opt_name)
except (ConfigParser.NoOptionError, ConfigParser.NoSectionError):
log_conf[opt_name] = opt_default
_parseOptions(log_conf)